RAW12018-10-30T22:13:02+08:00

Project Description

RAW1

• 2A×1 (1 from U)
• Max. carrying current 60A
• 1 from U type


Coming soon

Coil data
Rated voltage12 V
Rated current3: 75 mA, 4: 53.3 mA, 5: 37.5 mA
Operating power3: 900 mW, 4: 640 mW, 5: 450 mW
Response voltage3: 7.7 V DC, 4: 9.0 V DC, 5: 10.5 V DC
Drop out voltage3: 0.8 V DC, 4: 0.8 V DC, 5: 0.8 V DC
Coil resistance3: 160 Ω ±10%, 4: 225 Ω ±10%, 5: 320 Ω ±10%
Usable voltage range10 ~ 16 V DC
Operating timeMax. 10 ms
Release timeMax. 10 ms
Contact data
Contact configuration2A×1 (1 from U)
Contact materialAg alloy
Nominal switching capacity60 A 14 V DC
Max. carrying current ※160 A for 1 hour (12 V DC, 20 ℃)
Min. load ※21 A 14 V DC (20 ℃)
Rated contact voltage14 V DC
Contact resistanceTyp. 3 mΩ (DC 6 V 1 A)
Mechanical lifeMin. 1,000,000 ops. (at 120 cpm)
Electrical life ※3Resistive load: Min. 100,000 ops. (at nominal switching capacity, operating frequency: 1s ON, 9s OFF)
Motor load: Min. 100,000 ops. (45 A 14 V DC at motor lock condition, operating frequency: 0.5s ON, 9.5s OFF)
General data
Rated withstand voltage (Between contacts)500 Vrms for 1 min (Detection current: 10 mA)
Rated withstand voltage (Coil / Contact)500 Vrms for 1 min (Detection current: 10 mA)
Insulation resistanceMin. 100 MΩ (500 V DC, Measurement at same location as “Rated withstand voltage” section)
VibrationFunctional test: 10 ~ 100 Hz, Min. 44.1 m/s2 {4.5G} (Detection time: 10 µs)
Destructive test: 10 ~ 500 Hz, Min. 44.1 m/s2 {4.5G} (Detection time: X, Y direction 2 hours, Z direction 4 hours)
ShockFunctional test: Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11 ms, detection time: 10 µs)
Destructive test: Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6 ms)
Ambient temperature (Operation) ※4High heat-resistant / Pin in Paste type: -40~110 ℃
Operating humidityHigh heat-resistant / Pin in Paste type: 2~85%
Dimension L×W×H (mm)20.0×15.0x16.8
Weight (g)13
※1 Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions.
※2 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
※3 When using the lamp control type, please inquire our sales representativ.
※4 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value.
Model designationContact arrangementContact specificationHeat resistanceCoil resistance
RAW1-B*H3
RAW1B: 2A×1Blank: Standard typeH: High heat-resistant type3: 160Ω
R: Pin in Paste type4: 225Ω
5: 320Ω