RJE2020-06-12T08:45:25+08:00

Project Description

RJE

• 1 Form A/C
• Rated current: 10 A
• high sensitivity type
• Dielectric strength between coil & contact: 4,000 V AC
• Class F Coil
• Meets IEC 60079 Anti-Explosion standard

Coil data 
Coil input voltage3/5/6/9/12/24 V DC
Coil powerD Type: 400 mW, L Type: 200 mW
Response voltage< 75% (Room temp.)
Drop out voltage> 5% (Room temp.)
Operation time / Release timeLess than 8 ms / less than 5 ms
Contact data 
Contact numbers1 Form A/C
Contact materialAg alloy
Max. switching voltage30 V DC, 277 V AC
Max. swiching power1 Form A: 2,770 VA, 1 Form C: N.O. 1,385 VA, N.C. 831 VA
Contact ratings 10 A 125 V AC, 5 A 277 V AC, 10 A 30 V DC, N.O. 5 A 277 V AC, N.C. 3 A 277 V AC
Contact resistenceMax. 100 mΩ (1 A / 6 V DC)
Mechanical service life1×107 times
Electrical Service life (AC1)1×105 times
General data 
Rated withstand impulse voltage (Coil / Contact)4 kV AC / 1 min
Rated withstand impulse voltage (Between contacts)1 kV AC / 1 min
Surge voltage10 kV AC (1.2/50 μs)
Insulation Resistance1,000 MΩ (500 V DC)
VibrationMalfunction 10~55 Hz (Amplitude 1.5 mm)
 Endurance  10~55 Hz (Amplitude 1.5 mm)
ShockMalfunction 98 m/s2, Endurance 980 m/s2
Ambient temperature (Operation)-40~105 ℃ (No condensation)
Operating humidity20~85%
Dimension L×W×H (mm)19.8×9.9×15.2
Enclosure typeFlux-proof, sealed
MountingPCB
Weight (g)7
Compliance certification numbercULus:E345228, TUV:R50246903, CQC:CQC12002084196, VDE:40045973
Model designationNumber of polesCoil voltageCoil powerContact configurationContact materialInsulation classEnclosure typeSpecial request
RJE-112DM*F-SXXX
RJE1:1 pole03:3 VD:400 mWM:1 Form ABlank:AgSnO2Blank:class ABlank:flux-proof335:
05:5 VL:200 mWBlank:1 Form COther numbers:other materialsF:class FS:sealedaccordance with IEC 60335-1
06:6V
09:9 V
12:12 V
24:24 V
RJE Version 3.01 MB